  • MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

     


    Manufacturer : MTL Instruments

  • MTL4541

  • 16ch AIO 4-20mA

  • REPEATER POWER SUPPLY

  • 4/20mA, HART®, 2- or 3-wire transmitters

  • Number of channels : One

  • Location of transmitter : Zone 0, IIC, T4–6 hazardous area if suitably certified, Div. 1, Group A hazardous location

  • Safe-area output

  • Signal range: 4 to 20mA

  • Under/over-range: 0 to 24mA

  • Safe-area load resistance (MTLx541) : @ 24mA: 0 to 360Ω @ 20mA: 0 to 450Ω

  • Safe-area load (MTLx541S) : Current sink: 600Ω max.

  • Maximum voltage source: 24V dc

  • Safe-area circuit output resistance: > 1MΩ

  • Safe-area circuit ripple : < 50μA peak-to-peak

  • Hazardous-area input : Signal range: 0 to 24mA (including over-range), Transmitter voltage: 16.5V at 20mA

  • Transfer accuracy at 20°C : Better than 15μA

  • Temperature drift : < 0.8μA/°C

  • Response time : Settles to within 10% of final value within 50μs

  • Communications supported : HART (terminals 1 & 2 only)

  • LED indicator : Green: power indication

  • Maximum current consumption (with 20mA signal) : 51mA at 24V

  • Power dissipation within unit (with 20mA signal) : MTLx541 0.7W @ 24V dc, MTLx541S 1.0W @ 24V dc

    MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

  • Safety description
    Terminals 2 to 1 and 3: Uo=28V Io=93mA Po=651mW Um = 253V rms or dc
    Terminals 1 to 3: Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open-circuit voltage <28V

  • Shipping Weight : 1 Kg


     

    SPECIFICATION of MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

    See also common specification
    Number of channels
    One
    Location of transmitter
    Zone 0, IIC, T4–6 hazardous area if suitably certified
    Div. 1, Group A hazardous location
    Safe-area output
    Signal range: 4 to 20mA
    Under/over-range: 0 to 24mA
    Safe-area load resistance (MTLx541)
    @ 24mA: 0 to 360Ω
    @ 20mA: 0 to 450Ω
    Safe-area load (MTLx541S)
    Current sink: 600Ω max.
    Maximum voltage source: 24V dc
    Safe-area circuit output resistance: > 1MΩ

    MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

    Safe-area circuit ripple
    < 50μA peak-to-peak
    Hazardous-area input
    Signal range: 0 to 24mA (including over-range)
    Transmitter voltage: 16.5V at 20mA
    Transfer accuracy at 20°C
    Better than 15μA
    Temperature drift
    < 0.8μA/°C
    Response time
    Settles to within 10% of final value within 50μs
    Communications supported
    HART (terminals 1 & 2 only)

    LED indicator
    Green: power indication
    Maximum current consumption (with 20mA signal)
    51mA at 24V
    Power dissipation within unit (with 20mA signal)
    MTLx541 0.7W @ 24V dc
    MTLx541S 1.0W @ 24V dc

    Safety description of MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

    Terminals 2 to 1 and 3:
    Uo=28V Io=93mA Po=651mW Um = 253V rms or dc
    Terminals 1 to 3:
    Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
    without further certification into any IS loop with an open-circuit
    voltage <28V

     

    SIL capable
    These models have been assessed for use in
    IEC 61508 functional safety applications.
    See data on MTL web site and refer to the
    safety manual




    Part Number & Description of MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters
     
    Digital Input
     
    MTL4501-SR     1ch DI failsafe solid-state output + LFD alarm        
    MTL4504          1ch DI relay output + LFD alarm + phase reversal
    MTL4510          4ch DI solid-state output        
    MTL4510B        4ch DI multifunction solid-state output
    MTL4511          1ch DI relay output
    MTL4513          2ch DI solid-state output        
    MTL4514/B       1ch DI relay output + LFD alarm     
    MTL4516          2ch DI relay output
    MTL4516C        2ch DI with changeover relay output     
    MTL4517          2ch DI relay output + LFD alarm     
     
    Digital Output
     
    MTL4521          Loop powered solenoid driver
    MTL4521L         Loop powered solenoid driver IIC    
    MTL4523          Solenoid driver with LFD
    MTL4523L         Loop powered solenoid driver + LFD       
    MTL4523R         Solenoid driver with LFD
    MTL4523V/VL    Solenoid/Alarm driver with voltage control    
    MTL4524           Switch operated solenoid driver     
    MTL4524S         Switch operated solenoid driver, 24V override       
    MTL4525           Switch operated solenoid driver low power   
    MTL4526           2ch switch operated relay      
     
    Analogue Input of MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters

    MTL4541           1ch 2/3 wire Transmitter repeater
    MTL4541A         1ch Transmitter repeater, passive input         
    MTL4541AS       1ch Transmitter repeater, passive input, current sink   
    MTL4541B          MTL4041B replacement
    MTL4541P          MTL4041P replacement
    MTL4541S          1ch 2/3 wire Transmitter repeater, current sink    
    MTL4544            2ch 2/3 wire Transmitter repeater
    MTL4544A          2ch Transmitter repeater, passive input         
    MTL4544AS        2ch Transmitter repeater, passive input, current sink   
    MTL4544B          MTL4044 replacement   
    MTL4544D          2/3 wire transmitter repeater, dual output   
    MTL4544S          2ch 2/3 transmitter repeater, current sink    
     
    Analogue Output
    MTL4546            1ch 4-20mA smart isolating driver + LFD        
    MTL4546C          1ch 4-20mA smart isolating driver + oc LFD   
    MTL4546Y          1ch 4-20mA smart isolating driver + oc LFD   
    MTL4549            2ch 4-20mA smart isolating driver + LFD        
    MTL4549C          2ch 4-20mA smart isolating driver + oc LFD   
    MTL4549Y          2ch 4-20mA smart isolating driver + oc LFD   
     
    Temperature Input
    MTL4575            1ch Temperature converter with alarm
    MTL4576-RTD     2ch Temperature converter, RTD   
    MTL4576-THC     2ch Temperature converter, THC   
    MTL4581            1ch mV/THC isolator for low-level signals     
     
    Pulse and Vibration
    MTL4531            1ch vibration probe interface
    MTL4532            1ch pulse isolator, digital or analogue output         
    MTL4533            2ch vibration probe interface
    Fire and Smoke
    MTL4561            2ch loop-powered, for fire and smoke detectors  
     
    General
    MTL4599             Dummy isolator      
    MTL4599N           General purpose feed-through module


    MTL4541 REPEATER POWER SUPPLY 4/20mA HART 2 or 3 wire Transmitters


    We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
     
    We mainly supply YOKOGAWA,WEIDMULLER, ABB, MOELLER, SCHNEIDER ElECTIC,FUJI,OMRON,HONEYWELL,SIEMENS,FLUKE,PEPPERL+FUCHS,HIMA,Endress+ Hauser etc.
     
    Why choose us?
     
    1. 100% original product, 100% quality assurance.
    If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
     
    2. Varied payment methods.
    We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
     
    3. SHIPPING:
    We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
    It will take 3 to 7days to reach in your hands.
     
    Packaging:
    Imported with original packaging or standard export packing.Customize design is acceptable.
     
    Contact:
     
    HONGKONG XIEYUAN TECH CO., LIMITED
    Email:becky@hkxytech.com   Web:www.hkxytech.com
    Mobile:+86-15972186287(Whatsapp & Wechat)

Previous:MTL5516C Switch Proximity Detector Interface 2 Channel with Next:MTL5541 Repeater Power Supply 4/20mA HART for 2 or 3 Wire Tr
 Footer begin -->